Tell us about your part, quantity, and key requirements. Nova Precision Manufacturing Co.,Ltd can help you choose suitable materials and manufacturing processes for your project.

How to specify holes for PEM self-clinching nuts, studs and standoffs: hole size, sheet hardness, edge and bend spacing, laser versus punched holes, finishing order and RFQ checklist.
A PEM self-clinching nut, stud, or standoff holds only as well as the hole it is pressed into. The fastener is squeezed into a prepared hole, and the surrounding sheet cold-flows into an undercut on the fastener body. Hole diameter, sheet hardness, edge distance, and finishing sequence therefore decide pushout and torque-out resistance. A hole that works for a loose bolt can be wrong for a clinch fastener. For design engineers, sourcing managers, and procurement teams buying chassis, brackets, and mounting plates, the practical question is what belongs on the drawing and what to confirm with the fabricator before hardware goes in. This guide covers hole size, sheet thickness, edge and bend spacing, laser-cut versus punched holes, and process sequence, based on published PEM data.
A clinch hole is a functional feature, not a clearance hole. Its diameter is set by the fastener part number rather than the thread size, it is held to a one-sided tolerance, and it is normally left without a chamfer or deburr. The PEM Self-Clinching Fastener Handbook lists five reliability factors: a properly sized hole, sheet thickness, sheet hardness, proper installation, and fastener quality. Four of the five are decided in the sheet metal shop or on the drawing.
Two points are easy to miss. First, the sheet must be softer than the fastener. If it is not, the fastener deforms instead of displacing sheet material into the undercut. Second, installation is a parallel squeezing operation, so tooling and press setup matter as much as the hole. A drawing note that says only “install PEM hardware” leaves too much to chance.
Match the fastener family to the sheet before you dimension the hole. The table below summarizes the recommendations in PEM’s CL self-clinching nut bulletin. It covers nuts only; studs and standoffs have their own bulletins and hole data.
| Nut type | Intended sheet material | Recommended sheet hardness | Design note |
|---|---|---|---|
| S / SS | Steel or aluminum | HRB 80 / HB 150 or less | General-purpose option for most carbon steel and aluminum panels |
| CLS / CLSS | Steel or aluminum | HRB 70 / HB 125 or less | Lower hardness limit than S/SS, so check sheet hardness first |
| CLA | Steel or aluminum (aluminum nut) | HRB 50 / HB 82 or less | Aluminum nut; the bulletin lists it for the softest sheets |
| SP | Stainless steel | HRB 90 / HB 192 or less | Panel should be annealed; PEM says not to install other nut types into stainless sheet |
| SMPS / SMPP | Steel or aluminum (SMPS); stainless (SMPP) | HRB 70 (SMPS); HRB 90 (SMPP) | Designed for sheet as thin as 0.64 mm; avoid placement next to bends |
Hardness limits come from the manufacturer’s bulletin. They are not a substitute for a mill certificate. If your sheet is a work-hardened temper, a hard-coat anodized aluminum, or a nitrided steel, ask the supplier to confirm actual hardness before choosing a fastener. The handbook specifically warns that processes such as hard coat anodizing and nitriding can raise panel hardness and make installation harder.
For stainless steel sheet, the handbook adds that 300-series stainless fasteners do not give enough hardness difference against stainless panels. It recommends A286 or 400-series fasteners instead.

The hole diameter comes from the fastener bulletin for the exact part number. It is not the thread size and it is not a standard clearance hole. In the bulletin, the metric hole sizes are given with a +0.08 / −0.00 mm tolerance, and the handbook says the equivalent inch tolerance of +.003 / −.000 must generally be held.
The following values come from the metric table for S-type nuts in the CL bulletin. The last column is a derived figure, explained in the spacing section below.
| Thread | Hole size in sheet (mm) | Min. hole centerline to sheet edge (mm) | Min. center-to-center spacing, derived (mm) |
|---|---|---|---|
| M3 × 0.5 | 4.20 +0.08 / −0 | 4.8 | about 6.9 |
| M4 × 0.7 | 5.38 +0.08 / −0 | 6.9 | about 9.6 |
| M5 × 0.8 | 6.33 +0.08 / −0 | 7.1 | about 10.3 |
| M6 × 1 | 8.73 +0.08 / −0 | 8.6 | about 13.0 |
Treat this table as a worked example. Bulletin revisions change, and other fastener families use different values. Confirm against the current PEM bulletin for the exact part number.
Two practical consequences follow from the tolerance. The window is only 0.08 mm wide and sits entirely above the minimum size, so a hole cut slightly small can stop the shank from entering and a hole cut slightly large reduces holding power. The handbook lists an oversized hole among the causes of fasteners falling out. The cutting process must therefore hold a tight diameter, and the inspection plan should measure it directly with a pin or plug gauge, not infer it from the program.
Location is the second half of the specification. As the guide on hole position versus hole diameter tolerance explains, diameter limits size and position limits where the axis sits, and one does not control the other. On a clinch hole the diameter window is already fixed by the hardware, so a maximum material condition modifier on position would add at most 0.08 mm of bonus tolerance. Define position to the datums that matter for the mating part, such as a PCB hole pattern or a cabinet mounting grid, and reserve tight position control for the holes that drive assembly.
Either route can work, and neither is automatically better. The handbook says mounting holes may be punched or drilled, and it flags laser cutting a mounting hole as one of the operations that can locally harden the sheet. Whether that matters depends on how much hardness margin the sheet has relative to the fastener. That margin is thinnest in stainless steel and in already-hard tempers, so those are the cases to validate first. This is an engineering inference from the PEM guidance, not a measured result for your material.
Punched holes bring a different issue. For sheet roughly 2.3 mm and thicker, the handbook recommends installing the fastener from the punch side, because the break-to-die side of the hole is larger. It also recommends keeping the punch sharp to limit work hardening, and suggests punching undersize and reaming, or changing the tooling direction, when the die-side hole is too large for the fastener.
The comparison of laser cutting versus CNC punching for sheet metal panels covers broader cost and geometry trade-offs, and those still apply. For clinch holes, add a few process-specific questions to the RFQ:
PEM tells users to determine the right installation force by test before production runs, and the same logic applies to hole preparation. A short trial lot on the actual sheet lot is cheaper than a field return of spinning standoffs.

Minimum sheet thickness depends on the fastener family and shank code. In the CL bulletin, S-type nuts in the smaller metric sizes are offered with shank codes that start at a minimum sheet thickness of 0.8 mm, and the M3 S nut, for example, steps through 0.8, 1.0, and 1.4 mm for shank codes 0, 1, and 2. The bulletin recommends using the maximum shank length that suits your sheet thickness for best performance. Thinner sheet needs a different family, such as SMPS or SMPP, which the bulletin lists for sheet as thin as 0.64 mm.
Thickness is also where gauge numbers cause trouble. Gauge numbers differ by material, so a “16 gauge” callout can resolve to different thicknesses in steel, stainless, and aluminum. The article on choosing sheet metal gauge for load-bearing brackets makes this point, and it also notes that thin sheet can dish or tear around a fastener, with local reinforcement or inserts as alternatives to raising the gauge of the whole part. For clinch hardware, specify thickness in millimeters with a tolerance, and make sure it falls inside the fastener’s shank-code range.
Use the published values, not a rule of thumb. Generic multiples of the fastener diameter can be too tight for one family and needlessly loose for another. Three constraints apply.
Edge distance. Too close to an edge, and the sheet can bulge or blow out. The handbook adds that the published centerline-to-edge distance applies to one edge only. If two edges are both at the minimum and unsupported during installation, the panel can distort and lose material from the undercut, reducing holding power. Corner locations deserve extra margin.
Bend proximity. For fasteners near a bend, the handbook says to apply the centerline-to-edge value from the hole to the outside of the bend radius. It also warns that a hole cut in the flat pattern before bending can elongate, and that bending after installation can distort the hole. The fix is to keep clinch holes outside the bend zone and to install hardware after forming.
Fastener-to-fastener spacing. The handbook gives a calculation: the centerline-to-edge value plus half the diameter of the second mounting hole. For an M3 S nut, that is 4.8 mm plus half of 4.2 mm, or about 6.9 mm center to center. Closer spacing can cause sheet distortion and “oil canning” between fasteners. This matters on dense PCB mounting plates, where hole patterns are set by the board and not by the fastener.
The common assumption is that a deburred, chamfered, or slightly generous hole is a better-quality hole. For a clinch fastener the opposite can be true. PEM’s guidance says not to deburr or countersink the mounting hole on either side, because that removes the metal that has to flow into the undercut. The handbook allows broken edges of no more than 0.005 inch (0.127 mm). A slightly oversize hole has a similar effect, since less sheet material is available to clinch.
This does not mean a rough hole is acceptable. Heavy dross, a tapered cut wall, or a large burr can interfere with seating the fastener square, so agree an acceptance criterion for these holes. The criterion differs from the one used for the rest of the part. Nova’s sheet metal fabrication workflow describes removing burrs and dross before bending and hardware installation, which is normal practice. It is worth stating on the drawing that PEM holes are excluded from deburring and chamfering while the perimeter and other edges are treated normally.
Finishing sequence matters for the same reason:
The handbook’s troubleshooting guidance maps well to design-stage checks. The table groups the failures a buyer is most likely to see on sheet metal plates and chassis.
| Symptom | Likely causes from PEM guidance | Design or RFQ fix |
|---|---|---|
| Fastener spins or falls out | Oversized hole, countersunk or deburred hole, insufficient force, sheet too hard, locally hardened hole, large die-side hole on thick punched sheet | Specify hole per bulletin, exclude deburring, confirm hardness, define install side, run a trial lot |
| Weak hold near a bend | Hole distorted by bending, or hardware installed before forming | Keep holes clear of the bend zone, install after forming |
| Edge bulge or blow-out | Hole closer to edge than published minimum, or multiple close edges | Use published distance, add margin at corners, ask about edge-support tooling |
| Distortion or oil canning between fasteners | Spacing too tight | Apply the spacing calculation, review dense patterns |
| Fastener sits cocked or off-square | Punch and anvil not parallel, shank not in the hole before pressing | Confirm tooling and process control with the supplier |
| Poor performance on finished panels | Installed over paint or powder coat, or before anodizing in aluminum | State the sequence on the drawing |
Plates carrying standoffs or studs concentrate several of these constraints in one part. The Nova product page for custom sheet metal mounting plates with PEM standoffs lists hole position, standoff location, mounting pattern, plate flatness, and hardware orientation as critical requirements to be defined on the customer drawing. That list is a useful checklist for any plate.

A fabricator can quote clinch hardware accurately only when the drawing removes ambiguity. Send:
Ask the supplier how holes will be cut, how diameter will be verified, and who installs the hardware and with what tooling. Specific answers suggest the drawing has been reviewed properly. Teams comparing finished part types can browse the custom sheet metal parts category and send drawings for engineering review.
What size hole does a PEM self-clinching nut need?
The hole size is defined by the specific part number and shank code, not by the thread size. For example, PEM’s CL bulletin lists 4.20 mm +0.08/−0 for an M3 S-type nut. Always confirm against the current bulletin.
Can PEM fasteners be installed in laser-cut holes?
Often, but validate them. PEM guidance lists laser cutting among the operations that can locally harden the sheet around a hole. Run an installation trial with pushout or torque-out checks on the actual sheet material before production.
Should I deburr or countersink a hole before installing a PEM nut?
No. PEM says not to deburr or countersink clinch holes, because that removes the metal needed to form the interlock. The handbook allows broken edges of no more than 0.005 inch (0.127 mm).
How close can a PEM nut be to a sheet edge or bend?
Use the minimum centerline-to-edge distance for the exact part number, for example 4.8 mm for an M3 S nut. Near bends, apply that distance to the outside of the bend radius, and install the hardware after forming.
Should PEM hardware be installed before or after powder coating?
Install it on bare, plated, or anodized sheet, not over paint or powder coat, because PEM says coating diminishes fastener performance. If painting follows installation, mask the threads with thread masking plugs.
Can PEM nuts be installed in stainless steel sheet?
Yes, with the right type. PEM recommends SP or SMPP nuts for stainless sheet, with the panel in the annealed condition and hardness within the limit for that type. Standard S-type nuts and 300-series fasteners are not recommended.
What is the minimum sheet thickness for a PEM nut?
It depends on the type and shank code. In the CL bulletin, small S-type nuts start at 0.8 mm for the shortest shank code, and SMPS or SMPP types are listed for sheet as thin as 0.64 mm.