Drawing, GD&T, and Inspection Requirements
The 3D CAD model defines nominal geometry, while the released 2D drawing should define what must be controlled. Include datums, critical dimensions, tolerances, fits, threads, GD&T, surface roughness, material grade, heat treatment, finish, masking, cosmetic zones, assembly notes, and the drawing revision.
When referencing ISO 2768-1, specify the applicable edition and tolerance class. When referencing ASME Y14.5, specify the applicable edition and show the required GD&T controls on the drawing.
Standard inspection verifies conformance to the accepted drawing and order requirements. Dimensional reports, First Article Inspection, certificates of conformance, material or finish certificates, traceability records, PPAP documentation, and custom sampling plans can be quoted when requested before production.